KHIA headerKnow-How in Action

VOL XXII, NO 134

Belzona® Clears Clarifier Problem

 
 

Industry:

Water / Wastewater (WATR)

 
 

Application:

Tanks and Chemical Containment Areas (TCC)

 
 

Customer Location:

Waste Water Utility, Oklahoma

 
 

Application Date:

March, 2007

 
 

Application Situation:

The aluminum shield on the clarifier extends 16 inches below the water line. This is the only one serving this small city.

 
 

Problem:

50% of the shield had been eroded away due to corrosion at the water line. A new skirt from the manufacturer would cost over $15,000 and take unduly long to install.

 
 

Products:

Belzona® 3921 (GSC Conditioner)Belzona® 5811 (immersion Grade)

 

Substrate:

Aluminum

 
 

Application Method:

Abraded new aluminum panels and coated with Belzona® 3921 and Belzona® 5811 in accordance with Belzona Know-How System Leaflet TCC-5. The panels were then bolted to the sound skirt eliminating need for complete replacement.

 
 

Belzona Facts:

The city did this repair using $500 of Belzona and $1,000 in metal and supplies. It also took them only 1 day versus more than a week to replace the whole shield.

 
 

Photographs Description

ClarifierEroded AluminumPreparing the panelsFinished panels coated at the waterline on both sides

 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 