Four Belzona® Repaired Condensers Still In Service After 17 Years



Buildings & Structures (BSTR)



Centrifugal Pumps (CEP)


Customer Location:

Power station, Thailand


Application Date:

October 1993


Application Situation:

Four main condensers with a total of eight tube sheets



Corrosion pitting had occurred around the tubes as a result of bi-metallic corrosion effects and the chloride content of the used river water.



Belzona® 1311 (Ceramic R Metal)

Belzona® 1321 (Ceramic S Metal)



Carbon steel


Application Method:

The application was carried out in accordance with the Belzona Know-How System Leaflet HEX-1. Belzona® 1311 was used for rebuilding and Belzona® 1321 for the coating of the tube sheets.


Belzona Facts:

Since the application of the coating, regular inspections took place which proved the excellent performance of the Belzona coating. In 2005, the complete coating of the tube sheet was still intact without showing any signs of degradation. A further inspection in 2010, after 17 years in service, also showed that the coating was still in a good condition. Only 10% of the surface was locally damaged due to mechanical damage. These areas were quickly repaired with Belzona before the tube sheet was put back into service.


Photographs Description

  1. Corroded tube sheet before application in 1993 
  2. Standard application underway. Special care was taken to prevent contamination of substrate) 
  3. Inspection in 2005 
  4. Inspection in 2010
Case study pic one


 Case study pic two


 Case study pic three


 Case study pic four