KHIA header

VOL XVI, NO 73

Belzona® Restores This Fan Pump To Like New Condition

 
 

Industry:

Pulp & Paper (PLPR)

 
 

Application:

Centrifugal Pumps (CEP)

 
 

Customer Location:

Pulp and paper mill in Georgia, U.S.A.

 
 

Application Date:

February 1986

 
 

Application Situation:

35,000 GPM Gould’s Primary Fan Pump.

 
 

Problem:

Extreme graphitization had caused holes between the suction and discharge sides of this fan pump after only four years of operation.

 
 

Products:

Belzona ® 1311 (Ceramic R-Metal)

Belzona ® 1321 (Ceramic S-Metal)

 

Substrate:

Cast iron

 
 

Application Method:

The application was carried out in accordance with Belzona Know-How System Leaflets CEP-2, CEP-3 and CEP-5.

 
 

Belzona Facts:

The complete application from beginning to end took only three days. The pump rehabilitation, including cost of labor, machinery and products was only 15% of the cost of a new casing.

 
 