KHIA header

VOL XVIII, NO 24

Wet Floors Made Safe With Belzona

 
 

Industry:

Buildings & Structures (BSTR)

 
 

Application:

Floor Problem Areas (FPA)

 
 

Customer Location:

Hospital - Victoria, British Columbia, Canada

 
 

Application Date:

March 2002

 
 

Application Situation:

Non-slip safety system required on quarry tiled dish washroom and food preparation area floors which were constantly wet.

 
 

Problem:

Slippery, wet floors

 
 

Products:

Belzona® 1321 (Ceramic S-Metal)

 

Substrate:

Quarry tiles

 
 

Application Method:

Application was carried out in accordance with Belzona Know-How System Leaflet FPA-8.

 
 

Belzona Facts:

Because the floors were constantly wet, there was always a threat that a serious accident could take place at any moment. A non-slip coating had been applied to other areas of the kitchen floor but this had proved to be ineffective over the long term. The coating had also started to loose adhesion in various places increasing the possibility of bacteria growth between it and the tiles beneath.

 
 

Photographs Description

  1. Preparation underway using special silicon carbide grinding tool and template
  2. Masking completed and application of grip system in progress
  3. View of completed section of food prep area
  4. View of completed wash area
 
 
  View PDF version  
 
 