BELZONA SUPPORTS WINTER MAINTENANCE SYSTEM

KHIA ID: 4888
Industry: ()
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Kitchener, Ontario, Canada
Application Date: October 2013
Products:

Belzona 6111 (Liquid Anode)

Belzona 5111 (Ceramic Cladding)


Problem: The internal walls of the salt hopper were suffering from corrosion and salt would not flow to the screw auger at the bottom.
Photograph Descriptions
  1. External view of salt hopper
  2. Salt hopper prior to application
  3. Application
  4. Completed application in service
Application Situation
Large salt hopper is used to load road salt using a conveyor system.
Application Method
The application was carried out in accordance with Belzona Know-How System Leaflet TCC-5. The surface was prepared by abrasive blasting and then two coats of Belzona 6111 were applied. Providing additional corrosion protection two coats of Belzona 5111 were applied.
Belzona Facts
Belzona´s proven longevity in conjunction with the in-house accelerated weathering and salt spray testing, provide a long-term performance with no yellowing, loss of adhesion or gloss.