KHIA header

VOL XXVIII, NO 237

Belzona® Provides Savings By Sealing Floor

 
 

Industry:

Buildings & Structures (BSTR)

 
 

Application:

Floor Problem Areas (FPA)

 
 

Customer Location:

WA, USA

 
 

Application Date:

1992

 
 

Application Situation:

Large animal surgery room.

 
 

Problem:

The seams on the floor in the large animal surgery room had split open, allowing bacteria to flourish underneath. The floor had to be sealed.

 
 

Products:

Belzona 2221 (MP Fluid Elastomer)

Belzona 2911 (Elastomer QD Conditioner)

Belzona 9341 (Reinforcing Sheet)

 

Substrate:

Urethane

 
 

Application Method:

The floor was cleaned and disinfected, and then allowed to dry. A roughing tool was used to abrade the surface. Belzona 2911 was applied and allowed to cure. The area was masked off and Belzona 2221 was brushed on with Belzona 9341 to bridge the seam. The application was carried out in accordance with a modified version of Belzona Know-How System Leaflet FPA-6.

 
 

Belzona Facts:

Belzona solved the problem in a very cost-effective manner. The only alternative solution was a complete replacement of the flooring, which was deemed too expensive.

 
 

Photographs Description

  1. Drying the floor after cleaning
  2. Abrading the surface
  3. Applying Belzona 2221 over the seams
  4. Completed application
 
 
  View PDF version  
 
 