KHIA header

VOL XXIX, NO 46

Belzona® Protects Paper Mill Fan Pump

 
 

Industry:

Fluid Flow (FLOW)

 
 

Application:

Centrifugal Pumps (CEP)

 
 

Customer Location:

Oregon, USA

 
 

Application Date:

2013

 
 

Application Situation:

Split case pump.

 
 

Problem:

Pumping stock at 125˚F, with calcium carbonate added, goes through a boil out process using sodium hydroxide and phosphoric acid at 165˚F. With the wear on the casing, it is just a matter of time before the chemicals create a hole.

 
 

Products:

Belzona 1111 (Super Metal)

Belzona 1391T

 

Substrate:

Cast Iron

 
 

Application Method:

The pump was grit blasted. Belzona 1111 was used to fill all the pitting. Two coats of 1391T were brushed on.

 
 

Belzona Facts:

There were no alternatives. Even a new pump would need to be coated to handle the caustic/acid boil out.

 
 

Photographs Description

  1. Grit blasted, ready to be coated
  2. Filling pits with Belzona 1111
  3. Coating with Belzona 1391T
  4. Completed application to pump casing
 
 
  View PDF version  
 
 