Belzona Repairs & Protects Filters

KHIA ID: 549
Industry: Commercial Facilities (COMM)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Carbon steel
Customer Location: Five star hotel - Egypt
Application Date: December 2004
Products:

Belzona® Marine Metal

Belzona® 1341 (Supermetalglide)


Problem: Severe corrosion of the filters after the failure of its internal coating. The corrosion also caused many holes in the bodies of the filters which were leaking during operation.
Photograph Descriptions
  1. General view of the media filters
  2. Holes caused by corrosion
  3. Old coating failed
  4. Coating was completed after all holes were plugged
Application Situation
Media filters for the hotels swimming pool.
Application Method
Application was carried out in accordace with Belzona Know-How System Leaflets TCC-1 & TCC-5.
Belzona Facts
Previous coating had failed causing many holes and leaks. Belzona Marine Metal sealed all the holes, while Belzona® 1341 was used as a protective coating to prevent future corrosion. Belzona® 1341 also was chosen due to the fact that it is NSF Approved.