BELZONA STOPS TANK LEAK

KHIA ID: 5809
Industry: Power (POWR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Power Plant, Northern Texas, USA
Application Date: 2014
Products:

Belzona 1111 (Super Metal)

Belzona 1291 (ES-Metal)

Belzona 9311 (Reinforcing Tape)


Problem: Emergency water tank was thin walled and leaking. Welding produced more leaks. The tank could not be taken out of service. Thin wall and leaks needed to be fixed while the tank was full.
Photograph Descriptions
  1. Area to be repaired
  2. Stopping leaks
  3. Applying Belzona 1111
  4. Completed repair
Application Situation
Water Tank
Application Method
The application was carried out in accordance with Belzona Know-How System Leaflet TCC-1. The tank was blasted, which revealed three active leaks. The leaks were stopped with Belzona 1291. Then the entire area was coated with a fully reinforced Belzona 1111 with Belzona 9311.
Belzona Facts
To shut the plant down was over one million dollars. We eliminated the need for a forced shutdown.