KHIA headerKnow-How in Action


Belzona® Refurbishes Split Case Pump



Food & Drink (FOOD)



Centrifugal Pumps (CEP)


Customer Location:

Distillery, Glasgow, Scotland


Application Date:

May 2016


Application Situation:

The model of split case pump was no longer produced so spares were in short supply.



Pump had been experiencing erosion/corrosion. Damage had occurred to the existing coating & some of the underlying steel substrate had been eroded away. If another model of pump were to be installed in this instance the surrounding pipework would have to be modified.



Belzona 1111 (Super Metal)

Belzona 1341 (Supermetalglide)



Mild steel


Application Method:

The application was carried out in accordance with Belzona Know-How System Leaflets CEP-1 and CEP-3. The damaged areas around the wear rings were rebuilt with Belzona 1111 before the casing was coated with two coats of Belzona 1341.


Belzona Facts:

Using this method the pump was repaired/protected & ready for service without the need for any modifications of the pipework associated with it. Due to the low film thickness of Belzona 1341, no major changes to the pump head are expected.


Photographs Description

  1. Pump casing before
  2. Damage before
  3. Casing after application of Belzona 1341
  4. Completed application
Case study pic one


 Case study pic two


 Case study pic three


 Case study pic four


For more information about Belzona visit: