Application Situation:

Water Storage Tank.



Tank was suffering localised pitting and coating breakdown on deck plates and beam edges. Superior erosion resistant coating required to protect the vessel from further corrosion.



Belzona 1111 (Super Metal)

Belzona 1321 (Ceramic S-Metal)



Carbon steel


Application Method:

Application was carried out in accordance with Belzona system Leaflet TCC-5. After preparing substrate by grit blasting, Belzona 1111 was used to rebuild the areas of pitting and corrosion, and then coated with Belzona 1321 to provide erosion-corrosion protection in the lower section of the tank. .


Belzona Facts:

Belzona products safely protected the tank from corrosion and allowed a fast and easy back to service with an in-situ application. This avoided replacement of the equipment, making significant savings. Belzona 1321 is suitable for potable water use, making it the ideal coating for this scenario.


Photographs Description

1. Deck of tank showing areas affected by corrosion 2. Example of pitting on tank wall 3. Areas of corrosion and pitting repaired with Belzona 1111 4. View of completed application on water tank

Case study pic one


 Case study pic two


 Case study pic three


 Case study pic four