Roof above the office space has 4 large skylights.

 
 

Problem:

Under the influence of the sun skylights had broken around the fastening bolts allowing leakage of water into the rooms below whenever it rained.

 
 

Products:

Belzona 3111 (Flexible Membrane)

 

Substrate:

Bitumen

 
 

Application Method:

Application was carried out in accordance with Belzona Know-How System Leaflet RPA-3.

 
 

Belzona Facts:

Repair cost less than half the purchase and replacement costs of new skylights. Inspected in August 2016 repairs still in excellent condition and keeping offices dry.

 
 

Photographs Description

1. Washing damaged skylights 2. Application of Belzona 3111 onto the Belzona 3911 Conditioner 3. Rooftop view immediately after the repair. 4. Rooftop view August 2016

 
 
  View PDF version  
 
 