Belzona® 1212 Keeps Ro Water Flowing

 
 

Industry:

Power (POWR)

 
 

Application:

Valves, Pipes and Fittings (VPF)

 
 

Customer Location:

Thermal power plant, Warora, India

 
 

Application Date:

August 2016

 
 

Application Situation:

Pumping system in Reverse Osmosis (RO) water plant at a 2X300 MW Coal based power plant.

 
 

Problem:

Water leakage at 5-6 kg/cm² at 7 numbers of circumferential joints from inlet pipe of SAM turbo pump.

 
 

Products:

Belzona 1212

 

Substrate:

Stainless Steel 317 grade

 
 

Application Method:

Application was carried out in accordance with Belzona System Leaflet VPF-11. Leakages located on-line under operation. Surface preparation with hand grinder to prepare the substrate. Belzona 1212 incorporating two wraps of Belzona 9341 applied with system offline. System allowed to cure for 3 hrs at 30°C before bringing system back online.

 
 

Belzona Facts:

Belzona repair was fastest option ensuring power generation was not interupted.

 
 

Photographs Description

1. SAM Turbo Pump before repair 2. Wetting the surface with Belzona 1212 3. Finished repair

 