KHIA headerKnow-How in Action

VOL XX, NO 10, ELITE

Belzona® Provides Food For Thought

 
 

Industry:

General Industry (GIND)

 
 

Application:

Valves, Pipes and Fittings (VPF)

 
 

Customer Location:

Food Processing Plant, Manchester UK

 
 

Application Date:

July 1999

 
 

Application Situation:

Large exhaust duct bend

 
 

Problem:

Several holes in the weld seams and isolated pinholes. All surfaces showed signs of corrosion and existing paint work was cracked and peeling.

 
 

Products:

Belzona® 1111 (Super Metal)

Belzona® 6111 (Liquid Anode)

Belzona® 5111 (Ceramic Cladding)

 

Substrate:

Mild Steel

 
 

Application Method:

Application was carried out in accordance with Belzona Know-How System Leaflets VPF-1 and VPF-2.

 
 

Belzona Facts:

This system was selected to provide long term protection in the wet and polluted atmospheric conditions. This was coupled with its excellent appearance. The application is still performing well after six years.

 
 

Photographs Description

  1. Exhaust duct outlet 
  2. Exhaust duct bend 
  3. Exhaust duct repaired
 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 

 

 
 
For more information about Belzona visit: www.belzona.com