KHIA header

VOL XXI, NO 62

Holed Hydro Turbine Runner Repaired With Belzona

 
 

Industry:

Water / Wastewater (WATR)

 
 

Application:

Centrifugal Pumps (CEP)

 
 

Customer Location:

Hydroelectric plant, Vermont

 
 

Application Date:

January 2007

 
 

Application Situation:

Hydro Turbine runner with severe erosion damage

 
 

Problem:

Entrained solids and cavitation caused severe damage to the edges of the runner. Holes and pitting are evident on the runner vanes.

 
 

Products:

Belzona® 1121 (Super XL Metal)

Belzona® 1341 (Supermetalglide)

 

Substrate:

Steel

 
 

Application Method:

Application carried out in accordance with CEP-3 & CEP-5. In-situ blast to near white metal finish, rebuilding to fill pits and holes finally overcoating with two coats Belzona® 1341.

 
 

Belzona Facts:

Runner replacement would be a several million dollar process involving total removal of the generator sets and dismantling of the penstock. It was not an option. Rebuilding and protection with Belzona will prolong service life.

 
 

Photographs Description

  1. Damaged runner with holes
  2. Damaged runner with holes
  3. Grit blasted clean and ready for coating
  4. Finished runner
 
 
  View PDF version  
 
 
For more information about Belzona visit: www.belzona.com