KHIA headerKnow-How in Action

VOL XXII, NO 86

Belzona® Repairs And Seals Iron Gutter

 
 

Industry:

Buildings & Structures (BSTR)

 
 

Application:

Roof Problem Areas (RPA)

 
 

Customer Location:

Logistics Factory, Lancashire - UK

 
 

Application Date:

April 2007

 
 

Application Situation:

Traditional cast iron gutter 0.5 meters wide by 64 meters long

 
 

Problem:

The cast iron had over time corroded and the joints deteriorated allowing water to enter the internal fabric of the building.

 
 

Products:

Belzona® 3111 (Flexible Membrane)

Belzona® 3921 (GSC Conditioner)
Belzona® 9311 (Reinforcing Sheet)
 

Substrate:

Cast Iron

 
 

Application Method:

The application was carried out in accordance with Belzona Know-How System Leaflet RPA-6.

 
 

Belzona Facts:

The cost of the Belzona was a fraction of the replacement cost of the cast iron gutter which was the other alternative.

 
 

Photographs Description

  1. Blocked and corroded gutter
  2. Gutter drained ready for preparation
  3. Belzona fully reinforced Flexible Membrane system
  4. Completed application
 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 
For more information about Belzona visit: www.belzona.com