KHIA header

VOL XXII, NO 129

Pump Bell Mouth Rebuilt And Protected With Belzona

 
 

Industry:

Power (POWR)

 
 

Application:

Centrifugal Pumps (CEP)

 
 

Customer Location:

Power Station, Pakistan

 
 

Application Date:

May, 2006

 
 

Application Situation:

Main raw water pump

 
 

Problem:

The pump bell mouth was badly eroded/corroded due to water quality.

 
 

Products:

Belzona® 1311 (Ceramic R Metal)
Belzona® 1341 (Supermetalglide)
 

Substrate:

Cast iron

 
 

Application Method:

Application was carried out in accordance with Belzona Know-How System Leaflets CEP-3 & -5.

 
 

Belzona Facts:

Belzona saved both replacement costs and extended outage.

 
 

Photographs Description

  1. Corroded Bell Mouth
  2. Extent of the erosion apparent after grit blasting
  3. Rebuilding with Belzona® 1311
  4. Completed job after applying Belzona® 1341
 
 
  View PDF version  
 
 