KHIA ID: 580Industry: Water / Wastewater (WATR)
Application: MPT-Mechanical Power Transmission (MPT)
Substrate: SteelCustomer Location: Water supply company, Bulgaria
Application Date: March 2003Products:Belzona® 1111 (Super Metal)
Problem: Broken edge of the keyway seat. Insufficient contact area for the load transmission.
The worn keyway Surface prepared Keyway being bedded into Belzona