BELZONA EMERGENCY RECLAMATION OF A REFINER

KHIA ID: 953
Industrie: Pulp & Paper (PLPR)
Anwendung: PDP-Positive Displacement Pumps (PDP)
Substrat: Cast Iron
Standort des Kunden: Paper mill, United Kingdom
Antragsdatum: August 2000.
Produkte: Belzona® 1311 (Ceramic R Metal)
Belzona® 1321 (Ceramic S Metal)

Problem: Severe erosion in the refiner body and the end cover/door led to several holes necessitating repair
Fotobeschreibungen
  1. Refiner case prior to the application in 2000
  2. The August 2000 rebuild and coating
  3. After seven years and one intermediate coating, still in excellent condition. The repair area was between the top two bolt holes
  4. Close-up after application of another coat of Belzona® 1321
Anwendungssituation
Disc refiner
Anwendungsverfahren
The original application was carried out in accordance with Belzona Know-How System Leaflet PDP-6.

Belzona-Fakten
In 2004 the refiner was inspected and a further coat of Belzona® 1321 was applied. Now in December 2007 it has been checked again and found still to be in excellent condition.