| Belzona Protection Of Co2 Compressor | | | | Industry:General Industry (GIND) | | | | Application:Centrifugal Pumps (CEP) | | | | Customer Location:Soda plant, Bulgaria | | | | Application Date:October, 2005 | | | | Application Situation:100,000 m³/h multistage centrifugal compressor of CO2
| | | | Problem:Erosion/corrosion damages on the outlet section due to high temperatures (110°C), water injection and acid contaminated flue gas. | | | | Products:Belzona® 1311 (Ceramic R-Metal)Belzona® 1392 (Ceramic HT2) | | | | Substrate:Cast Iron | | | | Application Method:Application was carried out in accordance with a modified version of Belzona Know-How System Leaflets CEP-3,CEP-5 and SHM-7. | | | | Belzona Facts:No other effective alternative available. Stainless steel cladding was fit on the most damaged sections using Belzona® 1311 to provide further protection. Inspection after 6 months and 2,000 working hours of the unit reviewed only slight discolouration and loss of gloss. According to this application method five compressors have been protected in the plant. | | | | Photographs DescriptionErosion/corrosion damage to the internal surfaces reviewed after blastingBelzona® 1392 appliedBelzona® 1311 used to fix the stainless steel platesView of the protected internal profile after 2,000 working hours in service of application made in 2005 | |
| |