| Belzona Repeat Application On Pump Diffuser | | | Industry:Water / Wastewater (WATR) | | | Application:Centrifugal Pumps (CEP) | | | Customer Location:Pump manufacturer, Italy | | | Application Date:May 2007 | | | Application Situation:Pump diffuser and cover | | | Problem:Corrosion protection and efficiency enhancement of equipment | | | Products:Belzona® 1311 (Ceramic R Metal)
Belzona® 1341 (Supermetalglide)
Belzona® 5811 (Immersion Grade)
Belzona® 1121 (XL Metal) | | | Substrate:Stainless Steel and Cast Iron | | | Application Method:Application carried out in accordance with Belzona Know-How System Leaflets CEP-3 & -5. | | | Belzona Facts:Pump originally protected in 1985 with Belzona Erosion Corrosion Barrier (EC Barrier). The Belzona EC Barrier was still in good shape after the first application which was carried out in 1985 but in need of upgrade to enhance efficiency. | | | Photographs Description
- Belzona EC barrier after being in service for 22 years
- Belzona® 1311 used to resurface small areas
- Completed application of Belzona® 1341
- Application of Belzona® 5811 on Cover
| |
| |