KHIA headerKnow-How in Action

VOL XXV , NO 27

Belzona® Guides Gate Valve Repair

 
 

Industry:

Buildings & Structures (BSTR)

 
 

Application:

Centrifugal Pumps (CEP)

 
 

Customer Location:

Timber handling quay on the Ruhr in North-Rhine Westphalia, Germany

 
 

Application Date:

June 1997

 
 

Application Situation:

1400mm (55") NB Gate Valve

 
 

Problem:

On both of the trapezoidal guides in the body there was severe metal loss caused during operation of the gate. The material loss was on average 6-8mm, occasionally 10mm (0.4”), over a length of 1600mm (63”)

 
 

Products:

Belzona® 1111 (Super Metal)

 

Substrate:

Cast Iron

 
 

Application Method:

The application was carried out in accordance with Belzona Know-How System Leaflet VPF-4. The guides were grit blasted to remove the corrosion. Moisture was driven out of the cast iron, followed by a second grit blasting. Using forming methods the guides were rebuilt, and then deburred prior to reassembly.

 
 

Belzona Facts:

Since this initial application was carried out a further two valves have been completed for the customer.

 
 

Photographs Description

  1. Corrosion to the guides
  2. The completed application after forming
  3. Refitting the valve
  4. Finished repair
 