KHIA headerKnow-How in Action

VOL XXV, NO 36

Belzona® Repair Makes A Rivetting Story

 
 

Industry:

Buildings & Structures (BSTR)

 
 

Application:

Centrifugal Pumps (CEP)

 
 

Customer Location:

Oil Blender, Duisburg, North-Rhine Westphalia, Germany

 
 

Application Date:

June 1996

 
 

Application Situation:

Storage tank for petroleum fuels

 
 

Problem:

Some of the riveted seams were leaking through blistering of the anti corrosive paint. If the blisters were pierced then the fuel oil would leak out. The tank was 14m diameter and 9.85m high.

 
 

Products:

Belzona® 1111 (Super Metal)

Belzona® 1321 (Ceramic S Metal)

 

Substrate:

steel plating

 
 

Application Method:

Works were carried out in accordance with Belzona Know-How System Leaflet TCC-1. The leaking areas were prepared initially by wet slurry blasting, as the potentially explosive oil would not permit gritblasting or grinding. Belzona® 1111 was applied followed by Belzona® 9341 (Reinforcement Tape). Two coats of Belzona® 1321 completed the application.

 
 

Belzona Facts:

Belzona repairs allowed tank to be safely re-instated without hot work and proved totally successful until the tank was eventually de-commissioned.

 
 

Photographs Description

  1. Overview of tank
  2. Preparation of seams
  3. Application of Belzona® 1111
  4. Application of Belzona® 1321
 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 
For more information about Belzona visit: www.belzona.com