| Belzona Repairs Hydrogen Coolers And Piping | | | Industry:Power (POWR) | | | Application:Heat Exchangers (HEX) | | | Customer Location:Power plant in Texas, U.S.A. | | | Application Date:May 1999 | | | Application Situation:Erosion-corrosion on hydrogen coolers and piping | | | Problem:Years of erosion-corrosion on uncoated turbine cooler parts forced this customer to seek a repair solution as opposed to the high costs associated with replacement. | | | Products:Belzona® 1121 (Super XL-Metal)
Belzona® 1341 (Supermetalglide) | | | Substrate:Steel | | | Application Method:Application was carried out out in accordance with Belzona Know-How System Leaflets HEX-2 and VPF-2. | | | Belzona Facts:Use of Belzona® 1121 (Super XL-Metal) overlayed with Belzona® 1341 (Supermetalglide) allowed the hydrogen coolers to be repaired in a two-day process. | | | Photographs Description
- Close-up of erosion-corrosion in hydrogen coolers
- Erosion-corrosion in hydrogen piping
- Cooler heads being rebuilt with Belzona® 1121
- Finished pieces overcoated with Belzona® 1341
| |
| |