ABSORBER REPAIRED AND PROTECTED WITH BELZONA

KHIA ID: 3240
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Major chemical manufacturer, UK
Application Date: July 2010
Products:

Belzona® 1121 (Super XL Metal) Belzona® 1391 (Ceramic HT)


Problem: The bubbler throat on the absorber had developed a number of holes within the vessel compartment due to substrate erosion/corrosion.
Photograph Descriptions

Absorber throat extensively damaged by corrosion  Steel plates being bonded onto the absorber using Belzona® 1121  Cold bonding completed  Completed application with Belzona® 1391 coating applied.

Application Situation
Badly corroded throat area in absorber.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflets TCC-1 & TCC-5. A total of 16 handleable sections of pre-formed mild steel plate were cold bonded to the substrate using Belzona® 1121 to completely encapsulate the affected areas. Once the Belzona had cured, the plates were frost blasted and the entire repair area was protected with Belzona® 1391 to prevent further damage.
Belzona Facts
The application was completed within three days providing the client with minimum downtime and disruption to the facility. The Belzona was selected for its excellent erosion-corrosion resistance at elevated temperatures.