| Belzona Protects Coal Director | | | Industry:Power (POWR) | | | Application:Solids Handling Machinery (SHM) | | | Customer Location:Coal-fired Power Plant - Ontario, Canada | | | Application Date:June 2004 | | | Application Situation:Coal director for pulverizer | | | Problem:The steel plate on the coal director was worn through and in need of replacement. | | | Products:Belzona® 1812 (Ceramic Carbide FP) | | | Substrate:Carbon Steel | | | Application Method:Application was carried out in accordance with Belzona Know-How System Leaflet SHM-13. | | | Belzona Facts:New steel was put in place. Steel was hand prepared and Belzona® 1812 material was put down with 1/8" thickness. This Belzona system provides excellent abrasion resistance, while ensuring the coal moves as required. | | | Photographs Description
- Surface preparation
- Product was kept warm with the help of this steam pipe
- Completed application
| |
| |