| Corroded And Cracked Pipework Fixed With Belzona | | | Industry:General Industry (GIND) | | | Application:Valves, Pipes and Fittings (VPF) | | | Customer Location:Manufacturing company, Slough, UK | | | Application Date:May 2014 | | | Application Situation:Pipework at global paints and coatings company. | | | Problem:The pipe had corroded and cracked, leaking 10% Sodium Hydroxide. | | | Products:Belzona 1221 (Super E-Metal)
Belzona 1161 (Super UW-Metal) | | | Substrate:Steel | | | Application Method:Application was carried out in accordance with Belzona System Leaflet VPF-11. Surface preparation was carried out using an MBX Bristle Blaster as grit blasting was not an option. After stemming weep, the pipe was wrapped with Belzona 1161 incorporating Belzona 9341 (Reinforcement Tape). | | | Belzona Facts:The Belzona solution ensured the repair was carried out in as little amount of time as possible (just 4 hours), keeping downtime to a minimum. | | | Photographs Description1&2. Cracked and corroded pipework
3. Completed application | |
| |