Belzona® Repairs Corroded Heat Exchanger Flange

 
 

Industry:

Power (POWR)

 
 

Application:

Heat Exchangers (HEX)

 
 

Customer Location:

Power plant, Egypt

 
 

Application Date:

December 2004

 
 

Application Situation:

Heat exchanger

 
 

Problem:

The flange of the heat exchanger was corroded preventing correct sealing.

 
 

Products:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 1321 (Ceramic S-Metal)

 

Substrate:

Steel

 
 

Application Method:

Application was carried out in accordance with Belzona Know-How System Leaflets HEX-1 and HEX-3.

 
 

Belzona Facts:

The flange was repaired in one day and also provided long term protection.

 
 

Photographs Description

  1. General view of the flange
  2. Surface preparation of the flange
  3. Belzona® 1311 applied to the corroded areas
  4. Flange repaired and protected
 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 