BELZONA PROTECTS INTERNAL OF CHP STACK

KHIA ID: 6335
Industry: Pulp & Paper (PLPR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Mild Steel
Customer Location: Papermill, Scotland, UK
Application Date: May 2016
Products:

Belzona 1593


Problem: The stack had been experiencing corrosion issues from the chemicals within the flue gas stream. It was suspected that acids within this stream were condensing on the vertical wall of the stack & causing excessive corrosion around the localized area.Repairs had been attempted in the past by welding mild steel plates to the internals of the stack during shutdowns. This did not solve the problem & the base issue kept occurring year after year.
Photograph Descriptions

1. CHP Stack

2. Plates welded in place during previous attempted repairs

3. Base of the stack coated

4. completed Belzona 1593 coating

Application Situation
The stack of the plants CHP (Combined Heat & Power) unit
Application Method
Application was carried out in accordance with Belzona System Leaflet TCC-5. After grit blasting the surface a paste grade Belzona was used to smooth out pitting before applying a two coat system of Belzona 1593.
Belzona Facts
The Belzona solution solved the problem & kept the metal loss from reoccurring. All the work was carried out during a short shutdown.