Belzona Lines New Build Desalter with Belzona 1391T
Industry: Oil & Gas (OILG)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Carbon Steel
Customer Location: Iraq
Application Date: January 2017
Problem: Newly fabricated vessel which was required to have an internal protective coating.
Photograph Descriptions
1.Nozzle Insert
2.2nd Coating
3.Spark Test
4.Final
Application Situation
Operating Temperature Min/Norm/Max:20/58/70 , Service /Crude Oil + Water + Sour Gas and specified with Belzona internal lining and nozzle insert.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet TCC-5 and TCC-16b . Preformed nozzle inserts were created and bonded into small diameter nozzles to ensure continuity of protection.
Belzona Facts
Using the Belzona internal coating and nozzle inserts solution , the vessel will have a longer service life.