| Belzona Repairs Heat Exchanger End Covers | | | Industry:General Industry (GIND) | | | Application:Heat Exchangers (HEX) | | | Customer Location:Cement Works, Usje, Macedonia | | | Application Date:March 2005 | | | Application Situation:Heat Exchanger End Covers | | | Problem:Holes and cracks had appeared on the end covers due to freezing water. | | | Products:Belzona® 1111 (Super Metal)
Belzona® 1321 (Ceramic S-Metal) | | | Substrate:Steel | | | Application Method:Application was carried out in accordance with Belzona Know-How System Leaflet HEX-5. | | | Belzona Facts:The customer had previously tried to weld a steel patch on to the end covers but it had failed. There were no new end covers in the warehouse and to order some would have meant 3-4 weeks of down time, thus the customer was delighted when Belzona solved the problem within two days, saving time and money. | | | Photographs Description