BELZONA PROTECTION TO FOAM GLASS INSULATION ON TANK

KHIA ID: 70
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Styrofoam insulation
Customer Location: Chemical Plant in Louisiana
Application Date: September 1997
Products:

Belzona® 3211 (Lagseal Membrane)

Belzona® 9321 (Lagseal Reinforcing Sheet)


Problem: Protection for new insulation is required.
Photograph Descriptions
  1. Application begins to the foam glass insulation. 
  2. Work in progress.  
  3. The finished application. Seamless encapsulation and waterproof protection to the insulation with Belzona® 3211.
Application Situation
Foam glass insulation on roof of 70' diameter tank
Application Method
The application was carried out in accordance with Belzona Know-How Leaflet TCC-4.
Belzona Facts
It was necessary to protect the new insulation with a coating impermeable to water but with a certain water vapor permeability to allow any moisture to escape the insulation. The protective coating had to be impact resistant, have no VOC (volatile organic content), and be fire resistant. Belzona® 3211 meets all requirements.