Belzona® Protects Francis Turbine Runner

 
 

Industry:

Power (POWR)

 
 

Application:

Centrifugal Pumps (CEP)

 
 

Customer Location:

Electricity Producer, Slovakia

 
 

Application Date:

2014

 
 

Application Situation:

Francis Turbine Runner was suffered extensive damage.

 
 

Problem:

Erosion/Corrosion

 
 

Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1341 (Supermetalglide)

 

Substrate:

Steel

 
 

Application Method:

The application was carried out in accordance with the Belzona Know-How System Leaflets CEP-1, CEP-3 and CEP-5.

 
 

Belzona Facts:

This was not first Belzona protection of Francis turbine runner for this customer. The client was so pleased with performance of the previous repair they ordered this repair and for a another turbine.

 
 

Photographs Description

1. Turbine in very bad condition

2. Repair in progress

3. Repair in progress

4. Turbine like new

 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 
For more information about Belzona visit: www.belzona.com