Belzona Repairs Air Pipe Distributor

KHIA ID: 7596
Industry: General Industry (GIND)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Steel
Customer Location: Cement Producer, Slovakia
Application Date: 2016
Products:

Belzona 1111 (Super Metal)


Problem: Whilst the system was offline, condensed gases created corrosion (deep 3 mm) on the DN 125 air pipe distributor.
Photograph Descriptions

1. Air distributor after blasting.

2. Belzona 1111 plus reinforcement tape.

3. Full extent of the pipe.

4. Belzona application complete.

Application Situation
Fresh air distribution system in a coal mill.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet VPF - 11.
Belzona Facts
Due to the size and complexity of the pipe, there was an extremely long lead time on a replacement, as well as considerable costs. The Belzona repair restored strength to the pipe and prevented future corrosion damage.