Belzona's Preventive Protection for a Geothermal Plant Cyclone

KHIA ID: 7773
Industry: Power (POWR)
Application: ()
Substrate: Steel
Customer Location: France
Application Date: 2018
Products:

Belzona 5892

Belzona 1523


Problem: New equipment has to withstand extreme conditions such as high temperatures (around 100°C in immersion), high flow rates and high salt concentrations. It needs a protective coating that could prevent erosion and resist in immersion in hot brine at 100°C.
Photograph Descriptions

Equipment overview after grit blasting.

Protection with Belzona 1523.

Protection with Belzona 5892.

Protection with Belzona 5892.

Application Situation
Preventive application on a cyclone in a geothermal plant.
Application Method
The steel was grit blasted first, then all the surfaces in contact with brine and the inside of the exhausts were coated with Belzona 5892. Belzona 1523 was then used for the protection of the parts exposed to important erosion and high temperatures.
Belzona Facts