Belzona Refurbishes Several Storage Tanks

KHIA ID: 8103
Industry: (LOMU)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Italy
Application Date: 2017
Products:

Belzona 5111 (Ceramic Cladding)

Belzona 6111 (Liquid Anode)


Problem: This ecology park had an intervention from the public environmental monitoring authority as they had detected pollution problems. The site did not match environmental standards and required extensive maintenance.
Photograph Descriptions

1. First tank before application

2. Finished application of first tank

3. Overview of other tanks before refurbishment

4. Finished application overview of all tanks

Application Situation
Refurbishment of the external surfaces of several storage tanks.
Application Method
This application was carried out in accordance with Belzona System Leaflet TCC-05. The external surface of the first storage tank was grit blasted to Sa 2.5 before applying 2 coats of Belzona 6111 to provide long term corrosion protection, followed by 2 coats of Belzona 5111 for it's UV resistance. After the success of the first tank refurbishment a further 4 tanks were coated within the ecology park following the same procedure as the first.
Belzona Facts
460 Kg of Belzona 6111 and 210 Liters of Belzona 5111 were used to coat all 5 storage tanks with the ecology park.