Belzona 4341 Internal Lining Protection Against Chemical Attack.

KHIA ID: 8105
Industry: Chemical & Petrochemical (PETR)
Application: TCC-Tanks and Chemical Containment Areas (TCC)
Substrate: Steel
Customer Location: Poland
Application Date: 2018
Products:

Belzona 4341 


Problem: Chemical aggression condensation of hot burns caused the steel to corrode on the pipeline. Which led to perforation of the steel.
Photograph Descriptions

Picture 1: Visible wall perforation

Picture 2: Internal surface corrosion

Picture 3: Belzona coating 4341

Picture 4: General view of the installation

Application Situation
Phosphoric Plant Works discovered the plant equipment corroding at a fast rate, leading to perforation.
Application Method
The application was carried out in accordance with Belzona Know-How Leaflet TCC-03
Belzona Facts
Belzona 4341 was a proven solution to protect the internal surface lining against chemical attack.