Structural Reinforcement of Nozzle with Belzona SW II

KHIA ID: 8137
Industry: ()
Application: ()
Substrate: SA516 Gr 70
Customer Location: Sao Paulo, Brazil
Application Date: December 2018
Products:

Belzona 1311 (Ceramic R-Metal)

Belzona 1982 (Superwrap II)

Belzona 9381 (Carbon Fiber Reinforcement Mesh)

Belzona 9382 (Release Film)


Problem: Nozzle welded to the bottom of the tank showing accelerated signs of internal corrosion. Fluid: Oxygen Scavenger Pressure: 1 kg/cm2 Temperature: 26°C Original Wall Thickness: 8.7mm Final Wall Thickness: 4mm
Photograph Descriptions

1. Overall view of finished repair 2. Overall view of finished repair 3. Overall view of finished repair 4. Close-up view with metallic id tag

Application Situation
Nozzle of process vessel suffering from internal corrosion and significant thickness loss. A carbon fiber polymeric compliant repair was needed, to comply with the structural reinforcement design of the equipment, and allowing for its operational continuity and reliability.
Application Method
Surface preparation was performed in accordance with SSPC SP11 with a MBX, achieving the required surface roughness for the application. After surface cleaning to get rid of oil and contamination, Belzona 1311 was used to bond a metallic coupler. The Belzona Superwrap II system was then applied around the nozzle and in part of the tank wall, with a final thickness of 6mm.
Belzona Facts
Application performed on site with certified Belzona applicators in accordance with ASME PCC-2. By restoring the structural integrity of the equipment with a non-metallic repair the end user was able to save on a lot of labor and safety of its employees.