Belzona 7111 used to isolate vibration pads on 3 x Compressors

KHIA ID: 8399
Industry: Power (POWR)
Application: GSS-Gaskets, Seals and Shims (GSS)
Substrate: Concrete
Customer Location: Poland
Application Date: October, 2020
Products:

Belzona 71111


Problem: Replacing old washers on the foundation of the motor compressors to ensure stability would be timely and costly and have a large impact on the operation.
Photograph Descriptions

Image 1: Mixing Belzona 7111

Image 2: Pouring Belzona 7111

Image 3: Belzona 7111 close up

Image 4: Completed Job

Application Situation
The client at a gas power station in Poland needed to isolate the vibration on 3 motor compressors.
Application Method
In accordance with Belzona system leaflet GSS-12: 1. Unscrew the covers engine. 2. Turning the shaft into check the settings shaft (taking measurements when rotating the shaft, the so-called Springing the shaft) 3.Loosening the screws and screwing in spacer bolts, breaking up the old ones shims 4. Cleaning places of performance (pouring out) new washers 5.Preparation and sealing formwork for pouring Belzona 7111 6 Pouring out of Belzona 7111 7. Removal of formwork and tightening the screws with a force of 1100 Nm
Belzona Facts
The client needed as little disruption to the operation as possible.