| Belzona Repairs Chemical Storage Room Floor | | | Industry:General Industry (GIND) | | | Application:Floor Problem Areas (FPA) | | | Customer Location:Doncaster, UK | | | Application Date:March 2022 | | | Application Situation:A floor area in a chemical storage room had become worn over time due to both mechanical and chemical attack. | | | Problem:Steel tiles had failed in one area of a chemical storage area, leaving damaged concrete. Any repairs needed to be able to protect against water and general chemical use. | | | Products:Belzona 4131 (Magma-Screed)
| | | Substrate:Concrete | | | Application Method:All loose and friable materials were removed from the target area, using a wire brush, soft brush and compressed air. The area was conditioned using Belzona 4911 (TX-Conditioner). Following the conditioning, Belzona 4131 was applied, and were finished level with the rest of the floor. | | | Belzona Facts:This is quite an old site which has many areas of repairs to carry out. The costs of employing specialist concrete repair contractors isn't an option with the amount they have to do. Belzona's free, on-site training, delivered by the local sales engineer was welcomed by the busy maintenance team, making it possible for them to now carry out professional and durable repairs to all their problem areas, potentially saving up to £20,000 a year in contractors fees. | | | Photographs Description1. Target area identified for training purposes
2. Cleaning out the loose and friable materials
3. Belzona 4911 Conditioner mixed and applied
4. Belzona 4131 laid, compressed and smoothed to finish | |
| |