Corroded flange area rebuilt with Belzona

KHIA ID: 8853
Industry: Chemical & Petrochemical (PETR)
Application: VPF-Valves, Pipes and Fittings (VPF)
Substrate: Carbon steel
Customer Location: Scotland
Application Date: July 2022
Products: Belzona 4331 (Magma CR3),Belzona 9411 (Release Agent)

Problem: Welding in the area was not feasible due to the proximity of a mechanical seal & the depth of the metal loss

Corroded area around mechanical seal

Close up

Area prepared & wetted out with Belzona 4331

Belzona 4331 filled to replace the lost metal

Application Situation
A mild steel flange section at the top of a vessel had become corroded due to leaking acetic acid. A repair was required to reinstate the lost metal & provide future protection.
Application Method
The corroded area was prepared using power tools to achieve a surface profile. It was degreased & Belzona 9411 release agent was applied to the bolts that fitted around the mechanical seal housing. Belzona 4331 was then used to wet out the area before being poured in to fill the areas of metal loss.
Belzona Facts
The repair was carried out in one day. It was low hazard to the plant & personnel due to the cold application. This repair is much more corrosion resistant than the original mild steel, whilst also providing chemical resistance agaisnt the acetic acid.