KHIA headerKnow-How in Action

VOL XXVIII, NO 64

Belzona® Repairs And Protects Demineralisation Channels

 
 

Industry:

 
 

Application:

Tanks and Chemical Containment Areas (TCC)

 
 

Customer Location:

Nuclear Power Plant, Lancashire, UK

 
 

Application Date:

October 2007

 
 

Application Situation:

A channel used to contain and transport sulphuric acid.

 
 

Problem:

The concrete channel was deterioted from the acid. A previously applied protective coating had failed and allowed the concrete substrate to be attacked. This caused severe holes and damage to the channels.

 
 

Products:

Belzona 4181 (AHR Magma-Quartz)

Belzona 4911 (Magma TX Conditioner)

 

Substrate:

Concrete

 
 

Application Method:

The application was carried out in accordance with Belzona Know-How System Leaflet TCC-9.

 
 

Belzona Facts:

Time constraints due to demands on energy generation meant that Belzona were only allocated a short period of time for the repair work. Keeping to a schedule and force curing the product meant the power station incurred no fines for not being available to generate power when required.

 
 

Photographs Description

  1. Damaged concrete substrate
  2. Close up of damaged reinforced concrete substrate
  3. Filling in the prepared holes using Belzona 4181
  4. Completed channel
 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 