| Belzona Saves Refinery $50,000 | | | Industria:Fluid Flow (FLOW) | | | Áreas Know-How:Heat Exchangers (HEX) | | | Cliente / ubicación:Refinery - Sweeny, Texas USA | | | Fecha de aplicación:January 2003 and January 2008 | | | Situación de aplicación:Multiple heat exchanger components severely damaged by erosion/corrosion. | | | Problema:Galvanic corrosion and erosion resulting in loss of thickness and gasket sealing surfaces. This allows for working fluid to bypass portions of the multi-pass exchanger thereby greatly decreasing the efficiency of the heat exchanger. | | | Productos:Belzona® 1111 (Super Metal)
Belzona® 1321 (Ceramic S-Metal) | | | Substrato:Carbon Steel | | | Método de aplicación:Belzona® 1111 and Belzona® 1321 were applied in accordance with Belzona Know-How System Leaflet HEX-2. | | | Hechos Belzona:Conventional repair involves weld build up followed by the machining of new gasket surfaces at a cost of $2,500-$5,000 per dollar plate. The Belzona solution costs less than half of the conventional repair. This results in cost savings of more than $50,000 per unit turnaround. | | | Descripciones de fotografías
- Heat exchanger dollar plate prior to repair
- Heat exchanger dollar plate after repair and coating
- Heat exchanger after five years in service
- Heat exchanger channel head after five years in service
| |
| |