Belzona Repairs 24" Pipe Elbow

 
 

Industria:

Petrochemical (PETR)

 
 

Áreas Know-How:

Gaskets, Seals and Shims (GSS)

 
 

Cliente / ubicación:

Petrochemical Plant, Kuwait

 
 

Fecha de aplicación:

2001

 
 

Situación de aplicación:

24" Diameter pipe used to carry seawater

 
 

Problema:

Failure of the internal lining had lead to wall thinning and a through wall defect. NDT was used to define the thinned area.

 
 

Productos:

Belzona® 1311 (Ceramic R-Metal)

Belzona® 9341 (Reinforcement Tape)

 

Substrato:

Mild Steel

 
 

Método de aplicación:

A steel patch was welded into position in the area of the through wall defect. A base layer of Belzona® 1311 was applied followed by Belzona® 9341. The whole process was then repeated and a layer of Belzona® 1311 applied to give a smooth finish.

 
 

Hechos Belzona:

This repair was evaluated extensively by the maintenance team prior to being undertaken. Defects were ground into pipespools and the pipespools were then wrapped in the manner described above. These were then successfully pressure tested prior to undertaking the actual repairs.

 
 

Descripciones de fotografías

  1. Front view
  2. Side view
  3. Test piece being prepared for evaluation
 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 
Para obtener más información acerca de los productos Belzona visite: www.belzona.com