Belzona Repairs And Protects Quench Tower

 
 

Industria:

Petrochemical (PETR)

 
 

Áreas Know-How:

Tanks and Chemical Containment Areas (TCC)

 
 

Cliente / ubicación:

Petro Chemical Complex, Western India

 
 

Fecha de aplicación:

2012

 
 

Situación de aplicación:

Quench tower suffering Corrosion Under Insulation (CUI).

 
 

Problema:

The tall carbon steel tower contains many trays and is insulated to prevent heat loss. Water penetration and condensation had led to severe CUI in many localised areas. The thickness of tower walls had reduced by more than 50% in some areas.

 
 

Productos:

Belzona® 1251 (HA Metal)

Belzona® 5851 (HA-Barrier)

 

Substrato:

Carbon steel

 
 

Método de aplicación:

Application was carried out in accordance with a modified Belzona Know-How System Leaflet TCC-5. Due to the hazardous area and live tower, scope of surface preparation was limited. Spark free tools were used to remove all loose corrosion back to a sond substrate. Belzona® 1251 was used to repair pitted areas, using doubler plates bonded over the most severely corroded areas. The tower was coated to prevent further corrosion using Belzona® 5851.

 
 

Hechos Belzona:

The application was completed over the course of 18 days using around 250kg of Belzona® 1251. The work was completed with the tower in continuous service and the client was confident with Belzona’s solutions for such on-line CUI repairs and has subsequently placed a repeat order for the restoration and protection of 13 further towers.

 
 

Descripciones de fotografías

  1. Surface condition behind insulation at 7m height
  2. Severe damage due to CUI
  3. Application of Belzona® 1251
  4. Completed rebuild with high temperature barrier coating Belzona® 5851 applied to prevent further corrosion
 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 
Para obtener más información acerca de los productos Belzona visite: www.belzona.com