| Belzona Restores Corroded Pump Housing | | | Industria:General Industry (GIND) | | | Áreas Know-How:Centrifugal Pumps (CEP) | | | Cliente / ubicación:Drinking water supplier, Lisbon region, Portugal | | | Fecha de aplicación:November 2004 | | | Situación de aplicación:Horizontal split case centrifugal water distribution pump. | | | Problema:The pump had extensive corrosion. | | | Productos:Belzona® 1341 (Supermetalglide) | | | Substrato:Cast iron | | | Método de aplicación:Application was carried out in accordance with Belzona Know-How System Leaflet CEP-5 & CEP-10. | | | Hechos Belzona:Another, similar pump, had been coated with Belzona 6 years previously and recent inspection found it to be excellent condition so client had no hesitation in specifying Belzona again. | | | Descripciones de fotografías
- Corroded pump housing
- Corroded pump outlet
- Application of Belzona® 1341
- Competed application
| |
| |