KHIA headerKnow-How in Action

VOL XXI, NO 30, ELITE

Maintenance Of Belzona Coated Separator After 9 Years In Service

 
 

Industria:

Oil & Gas (OILG)

 
 

Áreas Know-How:

Tanks and Chemical Containment Areas (TCC)

 
 

Cliente / ubicación:

North Sea Platform, UK

 
 

Fecha de aplicación:

Nov 1997

 
 

Situación de aplicación:

In situ re-coat of the 1st stage separator in a time restricted shut down. Inspection in August 2006.

 
 

Problema:

Previous glass flake system had failed and had suffered corrosion damage to the vessel wall. Belzona inspected after 9 years and only problems caused by local areas of mechanical damage.

 
 

Productos:

Belzona® 1111 (Super Metal)

Belzona® 1391 (Ceramic HT)

 

Substrato:

Carbon Steel

 
 

Método de aplicación:

Application was carried out in accordance with Belzona Know-How System Leaflet TCC-3.

 
 

Hechos Belzona:

After 9 years in service, the vessel was returned to service with only the need for localized repairs.

 
 

Descripciones de fotografías

  1. Vessel being coated in 1997. 
  2. Vessel inspection in 2006. 
  3. Vessel Inspection 2006. 
  4. Localised Repair 2006.
 
Case study pic one

 

 
 Case study pic two

 

 
 Case study pic three

 

 
 Case study pic four

 

 
 
Para obtener más información acerca de los productos Belzona visite: www.belzona.com