ENHANCING PUMP EFFICIENCY WITH BELZONA

KHIA ID: 814
Industry: Buildings & Structures (BSTR)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Cast iron
Customer Location: Water supply station, Egypt
Application Date: February 2003
Products: Belzona® 1311 (Ceramic–R Metal)
Belzona® 1341 (Supermetalglide)

Problem: The efficiency of the pump had decreased due to the eroded casing and impeller.
Photograph Descriptions
  1. Pump removed from service
  2. Cavitated impeller
  3. Impeller rebuilt and coated
  4. Casing completed
Application Situation
Large centrifugal water pump.
Application Method
Application procedures were carried out in accordance with Belzona® Know-How System Leaflet CEP-5 & 10.
Belzona Facts
The pump casing and impeller were rebuilt to their original dimensions. As a result and with coating the casing and impeller with Belzona® 1341 the efficiency of the pump has been increased from 800 lit/sec. to 1100 lit/sec.