BELZONA RESETS BUSHINGS ON P&H SHOVEL

KHIA ID: 5276
Industry: Mining & Quarrying (MINQ)
Application: MPT-Mechanical Power Transmission (MPT)
Substrate: Cast steel / Bronze
Customer Location: BC, Canada
Application Date: 1992
Products:

Belzona 1111 (Super Metal)

Belzona 9411 (Release Agent)


Problem: The 16 inch diameter bores on the final drive of this P&H Shovel were badly worn.
Photograph Descriptions
  1. P&H Shovel.
  2. General view of disassembled P&H Shovel drive unit.
  3. New bushings coated with Belzona 9411. Prior to insertion oil and grease channels are filled with a firm paraffin wax to ensure they do not get blocked. Once set, the area is heated to soften the wax so that it can be pumped out with new grease.
  4. Completed application.
Application Situation
Worn bushings on P&H Shovel.
Application Method
The application was carried out in accordance with Belzona Know-How System Leaflet MPT-1.
Belzona Facts
This repair remained in service until the closing of the Shirley Basin Uranium Mine. Estimated savings in downtime and replacement costs were $125,000.00.