BELZONA RESTORES HUGE DYNAMOMETER

KHIA ID: 3116
Industry: Marine (MRNE)
Application: CEP-Centrifugal Pumps (CEP)
Substrate: Cast iron
Customer Location: Marine Engine Manufacturer, Croatia
Application Date: 2011
Products:

Belzona® 1121 (Super XL-Metal) Belzona® 5811 (Immersion Grade) Belzona® 1321 (Ceramic S-Metal)


Problem: Long years in service and chloride attack degraded the surface profile of the dynamometer.
Photograph Descriptions

Impeller Casing clearly showing degree of erosion present Protected impeller Protected casing

Application Situation
Hydraulic dynamometer used for engine tests.
Application Method
Application was carried out in accordance with Belzona Know-How System Leaflets CEP-1, CEP-3 and CEP-5. After the profile of the impeller and the casing had been rebuilt with Belzona® 1121, the whole dynamometer was protected with Belzona 5811. Finally Belzona® 1321 was used for extra protection for the casing and impeller blades.
Belzona Facts
The customer was very pleased that Belzona repair saved them from a very costly part replacement. Total savings was one million GBP.